Input Data
Max. DC power 4600 W
Max. DC voltage 600 V
Start voltage 150 V
DC nominal voltage 360 V
PV voltage range 100 V-600 V
MPP voltage range 120 V – 550 V
Number of independent MMP trackerts/strings per MMP tracker 2/2
Max. Input current of the MPP tracker 27 A/15 A
Grid Output data
Nominal AC output power 4600 w opt: 5000 w @240 v/127 v
Max. Output current 23.7 A @208 Vca/22 A @ 240 Vca/20.5 A @277 Vca
Max overcurrent protection device 67A
AC nominal voltage; range Default: 240V single phase, optional: 208 or 277  single phase, optional: 240Vsplit phase 183-228@208V,211-264V@240V 244-305 @277V
AC grid frequency; range 60 Hz; 59.3-60.5 Hz
Phase shift (cosꝔ) 1
THDI <3%
AC connection Single phase
Efficiency
Max. Eficiency 97.5 %
CEC efficiency 97%
MPPT efficiency 99.50%
Protection Devices
DC reverse polarity protection yes
DC switch for each MPPT yes
Output over current protection yes
Output overvoltage                    protection-varistor yes
Ground fault monitoring yes
AFCI compliant to UL 1699B yes
General Data
Dimensions (W / H /D) in inch 14.2 /25.6 /7.4
Weight 26 Kg / 57.3 Lb
Operating temperature range `=-25..+60C / -13…+140F
Noise emission (typical) ≤25dB (A)
Altitude Up to 2000m(6560ft) without power de-rating
Relative humidity 100%
Consumption: operating(standby) / night < 5w / < 0.5 w
Topology Transformerless
Cooling concept
Enclosure
Features
DC connection Screw terminal
AC connection Screw terminal
Display LCD
Interfaces: RS485/RS232/RF/WiFi/Ethernet yes/yes/opt/opt/opt/yes/opt
Warranty: 5 years / 10 years yes/opt